TL;DR
Compressor surge is a severe reversal of flow that can damage compressor internals. Check the anti-surge valve, operating point, and gas composition after any surge event.
What you might see
- audible banging or coughing from the compressor
- suction and discharge pressure oscillating rapidly
- vibration spike during the surge event
- compressor tripping on high vibration
Likely causes
Anti-surge valve failing to open quickly enough during a load reduction
Operating point driven past the surge line by a gas composition change
Compressor fouling from lube oil carryover increasing stage pressure drop
Suction throttle valve moving faster than the anti-surge system can respond
Required tools
- Anti-surge valve response timer
- Gas composition analyzer
- Vibration monitoring system access
- Oil sample kit
Safety first
- High-pressure hydrocarbon gas is present at the compressor suction and discharge during surge. Confirm gas containment before approaching after a surge event.
- Compressor surge on H2S-containing gas service requires gas detection before any work around the compressor.
- Do not restart after a surge event without a vibration check and an oil analysis to rule out bearing damage.
Procedure
- 1
After a surge event, stop the compressor per the emergency procedure and inspect for damage before restarting.
Warning: Compressor surge can cause impeller blade damage or bearing damage. Do not restart a compressor after a severe surge without an inspection. - 2
Review the surge event data from the control system. Confirm the anti-surge valve response time matches the design specification.[1]
- 3
Check the anti-surge valve stroke and response. A slow or stuck anti-surge valve cannot prevent surge during a rapid load shedding.[1]
- 4
Review the suction gas composition and molecular weight. A lighter gas shifts the surge line toward the operating point.
- 5
Inspect the anti-surge recycle piping and cooler for blockage.
- 6
After a surge event, take a lube oil sample from the compressor bearings and send for particle analysis to assess bearing condition.
- 7
Increase the anti-surge controller margin if the operating point is close to the surge line under normal conditions.
Sources
Solar Turbines (Caterpillar) Solar Mars 100 / Titan 130 / Centaur 50 Centrifugal Gas Compressor / Turbine general technical documentation, Solar Turbines (Caterpillar)
Solar Turbines Mars 100 / Titan 130 / Centaur 50 general compressor surge diagnosis and anti-surge system procedures (general)
More guides for Solar Turbines (Caterpillar) Solar Mars 100 / Titan 130 / Centaur 50
How to diagnose high exhaust temperature on a Solar Mars 100 / Titan 130 / Centaur 50 gas turbine
High exhaust temperature reduces turbine life and signals an efficiency problem. Check inlet air filtration, fuel control, and thermocouple calibration before adjusting firing temperature.
How to diagnose a lube oil system fault on a Solar Mars 100 / Titan 130 / Centaur 50 gas turbine
A lube oil system fault can trip the turbine and damage bearings. Check the oil pump, filter, and cooler in sequence to identify the root cause.
Related learning guides
Shaft Alignment Fundamentals
Precision alignment that prevents bearing, seal, and coupling failures.
Read guideWhat is Root Cause Analysis (RCA)?
Find the real failure point so the same fault stops showing up every month.
Read guideEquipment Breakdown Response
The step-by-step playbook for the first 15 minutes after a critical machine goes down.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.