TL;DR
A leaking wash pipe seal causes mud loss and can spray drilling fluid onto rig personnel. Replace the wash pipe packing at the earliest drill pipe connection.
What you might see
- drilling mud leaking from wash pipe area
- pressure drop at swivel during drilling
- mud volume gain in the active system
- wash pipe union showing wet marks
Likely causes
Wash pipe packing wear from abrasive drilling fluid
Wash pipe surface scoring creating a bypass path for fluid
Packing retainer loose or backed off from vibration
Wrong packing material grade installed for the mud weight and pressure
Required tools
- LOTO kit
- Torque wrench (for packing retainer)
- Replacement wash pipe packing kit
- PPE: face shield, chemical gloves, coveralls
Safety first
- Drilling mud is at high pressure at the wash pipe. Do not approach from below. Shut down mud pumps before any seal work.
- The rig floor is a dropped object hazard zone. All tools used at top drive height must be tethered.
- Lock out the top drive rotation and confirm zero rotation before touching any component of the wash pipe assembly.
Procedure
- 1
Identify the leak location at the wash pipe. Distinguish between the upper and lower packing areas.
Warning: Drilling mud is under high pressure at the wash pipe. Do not approach the leak from directly below. Wear face shield and chemical splash protection. - 2
At the next drill pipe connection, shut down the mud pumps and lock out the top drive rotation.[1]
- 3
Inspect the wash pipe body for scoring, grooves, or pitting. A scored wash pipe will not seal reliably even with new packing.[1]
- 4
Remove the packing retainer and old packing rings. Clean the packing chamber.
- 5
Install new packing of the correct grade for the mud weight and standpipe pressure. Torque the retainer to specification.
- 6
If the wash pipe body is damaged, replace the wash pipe assembly.
- 7
Restore pressure to the mud system and confirm the leak is eliminated before continuing to drill.
Sources
NOV (National Oilwell Varco) NOV TDS-11SA / Ideal Drilling Rig / Top Drive general technical documentation, NOV (National Oilwell Varco)
NOV TDS-11SA / Ideal top drive general wash pipe packing and seal replacement procedures (general)
More guides for NOV (National Oilwell Varco) NOV TDS-11SA / Ideal
How to diagnose an elevator link tilt actuator fault on an NOV TDS-11SA / Ideal top drive
A link tilt actuator fault stops pipe handling operations. Check the hydraulic supply, solenoid valve, and actuator cylinder before dispatching to the rig floor.
How to diagnose main shaft bearing failure on an NOV TDS-11SA / Ideal top drive
Rising vibration and bearing temperature on a top drive main shaft indicate bearing wear. Log baseline readings and plan a bearing inspection at the next stand connection opportunity.
Related learning guides
Electrical Fault Finding
Step-by-step electrical fault diagnosis for plant technicians.
Read guideVibration Analysis Basics
What your equipment is telling you before it fails.
Read guideBearing Replacement: When, Why, and How
The right-way guide to bearing replacement, and the warning signs you should never skip.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.