TL;DR
Tile weight variation from the press is almost always a powder feed carriage speed issue or a hopper level problem. Check the carriage stroke, fill shoe condition, and hopper level control before adjusting the fill weight.
What you might see
- tile weight variation above the control limit
- tile density non-uniform across the area
- feed carriage movement irregular or stopping
- powder level in the hopper varying erratically
Likely causes
Powder fill carriage drive worn, causing irregular stroke speed and variable fill time
Hopper level falling below the minimum, reducing gravity feed pressure to the fill shoe
Fill shoe wear reducing the contact surface and allowing powder to escape unevenly
Powder bridging in the hopper causing intermittent flow interruptions
Required tools
- Calibrated tile scale
- Carriage stroke measurement
- LOTO kit
Safety first
- Ceramic powder dust is a respiratory hazard. Wear P100 respiratory protection near the powder feed system.
- Full lockout before any inspection inside the press or feed system.
Procedure
- 1
Check the powder hopper level and refill to the operational range. Run the press for 10 cycles and weigh each tile.[1]
- 2
If tile weight is still variable, stop the press and lock out.[1]
- 3
Check the fill carriage stroke length and verify it is reaching the designed end position on each cycle.
- 4
Inspect the fill shoe wear surface. A worn shoe creates uneven powder distribution across the cavity.
- 5
Check the powder hopper agitator if fitted. A failed agitator allows powder bridging, especially with fine or moist powder.
- 6
After repair, run a 30-tile trial and weigh each. Control limits should be restored before resuming full production.
Sources
Sacmi Sacmi PH / PCR Series Tile Press general technical documentation, Sacmi
Sacmi tile press powder feed system maintenance documentation (general)
More guides for Sacmi Sacmi PH / PCR Series
How to detect and address mold wear causing tile dimension deviation on a Sacmi PH / PCR press
Tile dimension deviation is most often caused by mold wear. Measure the cavity dimensions during the next planned stop and replace or refurbish the mold when wear exceeds the tolerance.
How to diagnose hydraulic pressure loss on a Sacmi PH / PCR tile press
Low pressing force means the hydraulic pump is delivering below the rated pressure or the accumulator pre-charge is low. Check the pump output and accumulator before tracing individual cylinder seals.
Related learning guides
Bearing Replacement: When, Why, and How
The right-way guide to bearing replacement, and the warning signs you should never skip.
Read guidePump Failure: 8 Common Causes
The most frequent pump failure modes and how to prevent them.
Read guideMotor Troubleshooting: Symptoms to Fix
Read motor symptoms correctly and get to the root cause in minutes, not hours.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.