Dovient

Template

Veterinary controlled substance log

A controlled substance log for veterinary clinics, with the entries DEA rules expect for each dose, the biennial inventory, storage, and how long to keep the records.

What the DEA requires

A veterinarian who holds a DEA registration and dispenses or administers controlled substances, such as ketamine, butorphanol, buprenorphine, hydromorphone or phenobarbital, must keep records of every substance received and every dose dispensed or administered. The rules are in 21 CFR Part 1304. Your state board of pharmacy or veterinary medicine may add its own rules, so follow whichever is stricter.

  • Dispensing records: for each dose, the name and address of the person it was dispensed to (for a veterinary clinic, the client), the date, the drug and its form and strength, the number of units or volume dispensed or administered, and the name or initials of the person who dispensed or administered it (21 CFR 1304.22(c)).
  • Separation: keep Schedule I and II records separate from all other records. Schedule III to V records must be separate or readily retrievable from your ordinary records (1304.04(f) and (g)).
  • Retention: keep every inventory and record for at least 2 years, available for DEA inspection (1304.04(a)).
  • Biennial inventory: a complete count of every controlled substance on hand at least every two years, noting whether it was taken at the opening or close of business. Opened Schedule II containers need an exact count; opened Schedule III to V containers may be estimated unless they hold more than 1,000 tablets or capsules (1304.11).
  • Storage: Schedule II to V substances in a securely locked, substantially constructed cabinet (21 CFR 1301.75(b)).
  • Theft or significant loss: notify the DEA Field Division Office in writing within one business day of discovery, and file DEA Form 106 within 45 days (1301.76(b)).

How to keep the log

  1. Keep one running log per drug and strength, so the balance on each page matches one bottle type.
  2. Record every receipt from a supplier with the date, quantity and invoice or DEA Form 222 number for Schedule II.
  3. Record every dose at the time it is drawn up, with the patient, client, amount and initials.
  4. Record any waste with a second person as witness, as many state rules require.
  5. Carry the running balance forward on every line, and count the bottle against the balance on a set schedule, such as weekly.
  6. Investigate any difference the same day. Report theft or significant loss to the DEA as required.

What an inspector looks at

  • Logs that are complete, legible and balanced, with no gaps or unexplained corrections.
  • The last biennial inventory and its date.
  • DEA Form 222 copies for Schedule II orders and invoices for Schedule III to V.
  • A locked cabinet with limited key or code access.
  • Records of disposal through a reverse distributor or other permitted method.

Controlled substance dispensing log

One page per drug and strength; one line per dose, receipt or waste

DatePatient and client nameClient addressQuantity receivedQuantity used or wastedRunning balanceWitness (for waste)Initials

The printed log has 10 rows per page.

Run it in Dovient Lite

Keep the controlled substance log itself in your practice software or bound log. Dovient Lite can make sure the duties around it are done: add the controlled substance safe as an asset and set a weekly count check and a biennial inventory as scheduled work orders with a checklist, such as safe locked, counts match the log and keys accounted for. The person doing it marks each item pass, warning or fail on the phone, can attach a photo of the signed page, and the completed check is saved with who did it and when.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

What must a veterinary controlled substance log include?
For each dose: date, client name and address, drug, form and strength, amount dispensed or administered, and the name or initials of the person who gave it. Most clinics also keep a running balance.
How long do I keep controlled substance records?
At least 2 years under DEA rules. Some states require longer.
How often is a controlled substance inventory required?
DEA requires a full inventory at least every two years. Many clinics also count each drug weekly or monthly to catch problems early.
What do I do if the count is off?
Recount and check the log for missed entries. If you find theft or a significant loss, notify the DEA Field Division Office in writing within one business day and file DEA Form 106 within 45 days.