Dovient

Template

Landscape equipment maintenance log

A maintenance log for mowers, trimmers, blowers, trucks and trailers, with service intervals by engine hours and the records worth keeping. It is the core of landscaping maintenance for a crew that cannot lose a mower mid-season.

What the rules require

No federal rule requires a log for mowers and handheld equipment. OSHA does expect equipment to be kept safe to use: guards and shields in place, blade engagement and seat switches working, and workers trained on the machines (OSHA's landscaping safety page covers the main hazards). A log of repairs and checks is the easiest way to show that.

Trucks are different. A truck or truck and trailer with a gross vehicle weight rating of 10,001 pounds or more, used across state lines, is a commercial motor vehicle under 49 CFR 390.5, and many states apply the same rules inside the state. That brings a yearly inspection (396.17) and maintenance records kept for 1 year, and for 6 months after the vehicle leaves your control (396.3).

Lawn care maintenance schedule for equipment

  • Daily, before the trailer leaves: oil level, blades and blade bolts, belts, tire pressure, guards and chute, seat and blade switches, trailer hitch, chains and lights.
  • Every 25 to 50 engine hours: clean or replace the air filter, grease spindles and pivot points, sharpen blades.
  • Every 100 engine hours, or the interval in the manual: engine oil and filter on mowers.
  • Monthly on handhelds without hour meters: air filter, spark plug, fuel filter and trimmer head.
  • Hydraulic oil and filters on zero-turns: at the hours in the mower manual.
  • Trucks: oil and tire rotation by miles, and the yearly inspection.

Spring and fall checklist

Spring: change oil and filters, replace plugs, sharpen or replace blades, check belts and tires, charge or replace batteries, and test every safety switch before the first cut.

Fall: run fuel stabilizer or drain the tanks, change the oil so acids do not sit in the engine all winter, clean the decks, grease every fitting, and note the repairs to do over the winter. Writing these down in the log turns the off-season into a repair list instead of a scramble in March.

How to fill in the log

  1. Give each machine a number and write it on the machine.
  2. Record the engine hours or mileage every time you service it.
  3. Write what was done, the parts used and who did it.
  4. Add outside shop charges, so you know the real cost per machine.

Landscape equipment maintenance log

Each service or repair, per machine

DateMachine no.Engine hours or milesWork doneParts usedCost ($)Done by

The printed log has 10 rows per page.

Run it in Dovient Lite

Add each mower, trimmer, truck and trailer as an asset, or import your equipment list from a spreadsheet. Set schedules by engine hours, miles or date with a checklist attached; when a new hour reading is entered, a work order opens for anything due. Parts used on a repair come off stock and add to that machine's cost, so its record becomes the maintenance log, with every service, part and dollar on it.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

How often should a commercial mower be serviced?
Check it daily before use, clean the air filter and grease it every 25 to 50 hours, and change the engine oil about every 100 hours. Follow the engine and mower manuals where they differ.
Do I have to keep maintenance records for my landscaping trucks?
If a truck or truck and trailer is rated at 10,001 pounds or more and is used in interstate commerce, yes: FMCSA requires maintenance records and a yearly inspection. Check your state's rules for trucks used only in the state.
What should a landscaping equipment log include?
The date, the machine, the engine hours or miles, the work done, the parts used, the cost and who did it. That is enough to plan service and to see which machines cost too much to keep.