What the rules and guidelines say
There is no federal OSHA rule for playgrounds. The CPSC Public Playground Safety Handbook (Publication 325) is the national guideline, and many state child care licensing rules and inspectors use it. ASTM F1487 covers public playground equipment and ASTM F1292 covers how well surfacing absorbs a fall. Your state licensing rules set what is actually required for your center, so check them with your licensing consultant.
The CPSC handbook says to follow the manufacturer's inspection schedule, and where there is none, to set one based on use. Child care centers are high-use playgrounds and need frequent checks. Some states, Massachusetts among them, expect playground equipment to be checked every day before children use it.
Key numbers from the CPSC handbook
- Loose-fill surfacing such as wood chips or mulch: keep at least 9 inches deep. CPSC suggests an initial fill of 12 inches, because it compresses.
- Shredded rubber: 6 inches recommended.
- Use zone: at least 6 feet in all directions around stationary equipment, more for swings and slides.
- Openings between 3.5 and 9 inches can trap a child's head and should not be present.
- Rake loose fill back under swings and at slide exits often; it displaces fastest there.
How often to inspect
- Daily, before children go out: the walk-around items in the checklist below.
- Monthly: a detailed check of hardware, moving parts, surfacing depth and structure.
- Yearly or as your insurer or state asks: a full audit, often by a Certified Playground Safety Inspector.
- After storms or vandalism: a walk before the area is reopened.
Records to keep
CPSC recommends keeping records of all inspections and repairs, the manufacturer's maintenance instructions and the checklists used. The person who inspects signs and dates the form. Also keep a record of any injury reported on the playground; it helps you find the piece of equipment that needs fixing.
If something fails
Close the piece of equipment or the area with tape or a cone before children go out, and tell the other teachers. Report the problem to the director with a photo. Small items like raking mulch back can be fixed the same day; broken parts should be replaced with the maker's parts, following the maker's instructions, as CPSC advises.
Playground safety inspection
Daily before use; full list monthly
Daily walk
- No broken glass, trash or sharp debris
- No animal waste or standing water
- Gates close and latch, fence intact
- No ropes or cords tied to equipment
- Nothing too hot to touch on slides and decks
Surfacing
- Loose fill at least 9 inches deep
- Fill raked back under swings and slide exits
- Rubber tiles or mats not torn or lifted
- No hard objects or roots in the use zone
Equipment
- Bolts tight, end caps in place
- No cracks in plastic, no rust through metal
- No splintered, split or rotten wood
- Swing seats, chains and hangers not worn
- Guardrails and barriers secure
- Posts and anchors firm in the ground
Hazards
- No openings between 3.5 and 9 inches
- No protruding bolts or S-hooks left open
- No pinch or crush points at moving parts
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add the playground and each major structure as assets, print a QR label for the gate, and set a daily schedule with the daily items and a monthly schedule with the full list. A teacher marks each item pass, warning or fail on the phone with a photo of any problem, and the check is saved with who did it and when. Problems go in as a service request, the director turns them into work orders, and completed checks export as PDF for the licensing visit.
Start with Dovient LiteSources
- CPSC, Public Playground Safety Handbook, Publication 325, sections 2.5, 4.1 to 4.4, Appendix A
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often should a daycare playground be inspected?
- Check it every day before children use it, do a detailed check monthly, and get a full audit at least yearly. Your state licensing rules and the equipment maker may require more.
- Does OSHA regulate playgrounds?
- No. Playground safety is covered by CPSC guidelines, ASTM standards and state child care licensing rules. OSHA rules cover your staff, not the play equipment.
- How deep should mulch be under playground equipment?
- CPSC says never less than 9 inches of loose fill such as wood chips or mulch, with an initial fill of 12 inches because it compresses. Shredded rubber is 6 inches.
- What records should a daycare keep for the playground?
- Signed and dated inspection checklists, repair records, the manufacturer's maintenance instructions, and any injury reports, as CPSC recommends.