What ASTM F770 is
ASTM F770 is the Standard Practice for Ownership, Operation, Maintenance, and Inspection of Amusement Rides and Devices, written by ASTM Committee F24. It sets out what the owner and operator of a ride are responsible for: following the manufacturer's instructions, training operators, inspecting and maintaining each ride, and keeping records.
In practice that means each ride is inspected before it opens to the public each day, using the manufacturer's daily inspection list and your own procedures, and the inspection is written down and signed. A ride with a defect that affects safety stays closed until it is repaired and rechecked.
State ride safety programs
Most states have an amusement ride safety law, run by the department of labor, agriculture or a similar agency. It usually requires a permit for each ride, an inspection each year by the state or a qualified inspector your insurer accepts, reporting of serious injuries, and the operator's daily inspection and maintenance records. Many states adopt ASTM F770 and other F24 standards by reference. A few states have no state program and leave it to insurers and local governments. Check with your state agency for the rules that apply.
How to run the daily inspection
Keep daily inspections, maintenance, repairs, operator training and the state permit and inspection reports for each ride. Your state sets how long; keeping at least the current and prior season is common practice.
- Before opening, a trained inspector or operator goes through the manufacturer's daily list and the checklist below.
- Run the ride through at least one full empty cycle.
- Mark each item, sign and date the inspection.
- If anything fails, the ride stays closed. Open a repair, and reopen only after it is fixed and rechecked.
Daily amusement ride inspection
Daily, before opening to the public
Structure
- No cracks, bends or damage to structure
- Pins, bolts and keepers in place
- Footings and blocking solid and level
- Fencing, gates and queue line intact
Restraints and seating
- Lap bars, belts and harnesses lock and release
- Secondary restraints working
- Seats and padding secure, no tears
- Rider height signs posted
Mechanical
- Drive, chains and belts in good condition
- Wheels, bearings and brakes working
- No leaks of oil or hydraulic fluid
- Lubrication done per manufacturer
Electrical and controls
- Emergency stop stops the ride
- Operator controls and interlocks working
- Wiring and enclosures undamaged
- Lights and signals working
Test run
- Full empty cycle completed normally
- No unusual noise or vibration
- Manufacturer's daily checklist completed
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each ride as an asset with its location and print a QR label for its control box. Set a daily schedule with this checklist, plus the manufacturer's items, so a work order opens each morning. The inspector marks each item pass, warning or fail on the phone and adds photos; a failed item does not open a repair on its own, so they open a work order for the fix, and completed records export as PDF for the state inspector.
Start with Dovient LiteSources
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- Does ASTM F770 require daily ride inspections?
- It expects the owner or operator to inspect each ride before opening, following the manufacturer's instructions, and to keep records. Many states adopt it in their ride rules.
- Who can do the daily ride inspection?
- A person trained on that ride and its manufacturer's checklist. The yearly inspection is done by the state or a qualified inspector your state accepts.
- What records does a state ride inspector want?
- Signed daily inspections, maintenance and repairs, operator training, and the permit and last inspection report for each ride.
- What if a ride fails the daily check?
- It stays closed until the defect is repaired and the ride is rechecked. Record the failure, the repair and who returned it to service.