TL;DR
Warp tension inconsistency is usually a let-off brake drag, a damaged tension sensor, or uneven back-rest roller wear. Check the let-off torque setting and sensor calibration first.
What you might see
- warp tension alarm on the control panel
- lengthwise streaks in the fabric
- warp end breaks increasing
- fabric pick count variation within the beam
Likely causes
Let-off brake dragging from contamination or wear, causing tension surges
Warp tension sensor zero drift or damage giving incorrect feedback to the controller
Back-rest roller bearing wear causing uneven warp sheet movement
Warp beam winding taper mismatch with the let-off motor profile
Required tools
- Warp tension meter
- Brake pad inspection kit
- Bearing puller for back-rest roller
- Loom controller access for sensor calibration
Safety first
- The warp beam holds high potential energy from the warp tension. Never stand directly behind the beam end when adjusting the brake.
- Lock out the loom before working on the back-rest roller bearing. The roller can rotate unexpectedly when warp tension is released.
Procedure
- 1
Read the tension monitoring trend from the loom controller over the last 100 meters of warp. Identify whether tension rises steadily, fluctuates, or spikes.
- 2
Calibrate the warp tension sensor at zero load and compare the reading to the controller reference. Replace the sensor if calibration cannot be achieved.[1]
- 3
Check the let-off brake pad surface for oil contamination or wear. Clean or replace the brake pad if contamination is present.
- 4
Verify the let-off motor torque profile setting against the setup sheet for the warp beam diameter and yarn count.[1]
- 5
Rotate the back-rest roller by hand and check for rough bearing spots or radial runout. Replace the bearing if roughness is felt.
- 6
Adjust the tension set-point on the controller to the correct value for the article and monitor the first 10 meters of weaving.
Sources
Picanol Picanol OmniPlus 800 Loom (Air-Jet / Rapier) general technical documentation, Picanol
Picanol OmniPlus loom general warp let-off and tension control procedures (general)
More guides for Picanol Picanol OmniPlus 800
How to fix reed dent breakage on a Picanol OmniPlus 800 loom
Reed dent breakage is most often caused by a misdirected weft, an incorrect beat-up force setting, or a foreign object in the shed. Inspect the reed and remove broken dent fragments before restarting.
How to fix weft insertion fault on a Picanol OmniPlus 800 air-jet loom
Weft insertion faults are usually a blocked main nozzle, incorrect relay nozzle timing, or yarn tension out of spec. Check the main nozzle pressure and relay nozzle sequence first.
Related learning guides
Vibration Analysis Basics
What your equipment is telling you before it fails.
Read guideBearing Replacement: When, Why, and How
The right-way guide to bearing replacement, and the warning signs you should never skip.
Read guidePump Failure: 8 Common Causes
The most frequent pump failure modes and how to prevent them.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.