TL;DR
Drive belt slippage or noise is usually a worn or stretched belt or a misaligned pulley. Check belt tension and pulley alignment before ordering a replacement.
What you might see
- slapping or squealing sound from the drive area
- cylinder speed inconsistent at run speed
- belt dust accumulating below the drive enclosure
- speed alarm from the cylinder encoder
Likely causes
Belt stretched beyond the tensioner adjustment range from extended service
Belt wear on one section from a pulley misalignment causing edge loading
Pulley misalignment from a shifted motor mount after vibration
Foreign fiber material wrapped around a pulley, creating imbalance and noise
Required tools
- Torque wrench and socket set
- Straightedge for pulley alignment
- Replacement drive belt
- Fiber removal pick tool
Safety first
- Lock out the main drive motor before opening the drive guard. The belt is under tension and can snap if cut or released suddenly.
- The drive area accumulates fiber dust. Keep the area clear and avoid ignition sources near the fiber accumulation.
Procedure
- 1
Stop the machine and lock out the main drive motor.
- 2
Open the drive guard access panel and inspect the belt surface for cracking, glazing, fraying, or missing cog teeth.
- 3
Check belt deflection in the middle of the belt span by pressing with a finger. Excessive deflection beyond the manufacturer specification indicates a stretched belt.[1]
- 4
Check pulley alignment using a straightedge across both pulley faces. Misalignment greater than 1 mm requires adjustment.
- 5
Inspect all pulleys for fiber or debris wrapped around the hub. Remove any foreign material with a pick tool.
- 6
If the belt is worn or stretched beyond the tensioner range, replace the belt with the correct size and type per the machine specifications.[1]
- 7
Close the drive guard, restore power, and run the machine slowly for 2 minutes. Listen for noise and check the belt tension again after the first thermal cycle.
Sources
Mayer & Cie Mayer Relanit Knitting Machine (Circular / Flat) general technical documentation, Mayer & Cie
Mayer & Cie circular knitting machine general drive and belt maintenance procedures (general)
More guides for Mayer & Cie Mayer Relanit
How to fix fabric defects from yarn tension variation on a Mayer Relanit
Tension-driven fabric defects are usually an inconsistent yarn feed, a dirty yarn guide, or a feeder unit with a worn yarn wheel. Check tension at each feeder before adjusting any take-down parameters.
How to fix needle breakage on a Mayer Relanit circular knitting machine
Needle breakage is usually a bent needle hook, incorrect yarn tension, or worn cam track. Inspect the needle bed and cam tracks at the affected feeder before replacing individual needles.
Related learning guides
Motor Troubleshooting: Symptoms to Fix
Read motor symptoms correctly and get to the root cause in minutes, not hours.
Read guideLubrication Best Practices
The most overlooked maintenance task, and how to do it right.
Read guideShaft Alignment Fundamentals
Precision alignment that prevents bearing, seal, and coupling failures.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.