TL;DR
A converter fault on an induction power supply usually means a failed thyristor module or an overtemperature from blocked cooling. Check the fault code, then check the cooling air flow before replacing components.
What you might see
- power supply fault light on converter panel
- melt power limited below setpoint
- output frequency drifting from normal
- overtemperature alarm on the power supply cabinet
Likely causes
Thyristor module failed from overvoltage or overcurrent event
Cooling air flow to the converter cabinet blocked by a dirty filter or failed fan
Snubber capacitor failed causing uneven voltage sharing across thyristors
Gate drive circuit fault on one thyristor position
Required tools
- Multimeter for capacitor and gate circuit checks
- Replacement thyristor module (if needed)
- Filter cleaning or replacement
- LOTO kit for HV incoming power
Safety first
- High-voltage induction power supply. Only qualified personnel may work inside the converter cabinet.
- Lock out and verify zero energy on all incoming power circuits before opening the cabinet.
- Capacitors in the converter retain lethal charge after power-off. Follow the documented discharge procedure before touching components.
Procedure
- 1
Read the fault code from the power supply display and record it.
Warning: The induction power supply operates at high voltage (typically 480V to 13.8kV depending on configuration). Only qualified personnel with appropriate permits may work inside the converter cabinet. - 2
Isolate and lock out the incoming power to the converter before opening the cabinet.[1]
- 3
Check the converter cooling air filter and clean or replace if blocked.[1]
- 4
Verify the cooling fan in the converter cabinet is operating. A failed fan leads to rapid overtemperature.
- 5
If the fault code indicates a specific thyristor position, inspect that position for physical damage or discoloration.
- 6
If a thyristor module is failed, replace it with the specified replacement module. Consult the furnace manufacturer service documentation for the module specification.
- 7
After repair, restore power with reduced setpoint first and monitor the converter temperature for 10 minutes before returning to full power.
Sources
Inductotherm (Inductotherm Group) Inductotherm VIP-I / Power-Trak Induction Melting Furnace general technical documentation, Inductotherm (Inductotherm Group)
Inductotherm power supply service documentation, converter fault diagnosis and module replacement procedures (general)
More guides for Inductotherm (Inductotherm Group) Inductotherm VIP-I / Power-Trak
How to diagnose a coil ground fault on an Inductotherm VIP-I / Power-Trak induction furnace
A coil ground fault alarm means insulation breakdown between the induction coil and the furnace shell or ground. Stop melting immediately and test the coil insulation resistance before restarting.
How to monitor lining wear and prevent a breakout on an Inductotherm VIP-I / Power-Trak furnace
Lining wear beyond the minimum thickness is a breakout risk. Track the lining thickness every campaign and stop the furnace for relining when wear reaches the manufacturer's minimum allowed thickness.