TL;DR
Fouled superheater tubes raise flue-gas exit temperature and reduce steam output. Confirm by comparing exit temperature trend to baseline, then schedule sootblowing or offline cleaning.
What you might see
- rising flue-gas exit temperature
- reduced steam temperature at turbine inlet
- increased fuel consumption for same load
- sootblower frequency increased with diminishing returns
Likely causes
Carryover of sodium and potassium salts from the furnace depositing on tube surfaces
Insufficient sootblowing frequency during high-solids firing periods
Reduced steam-side velocity from low-load operation allowing deposits to accumulate
Plugged sootblower nozzle reducing effectiveness of cleaning cycles
Required tools
- DCS historian access
- Sootblowing sequence log
- Pressure gauge for sootblower steam header
- Camera for deposit documentation
Safety first
- Sootblower steam lines are at high pressure and temperature. Verify steam traps are functioning before starting a sootblowing sequence.
- Offline water washing requires full boiler isolation and lockout before personnel enter the superheater gas path.
Procedure
- 1
Pull the last 30 days of flue-gas exit temperature trends from the DCS historian and confirm a rising baseline.
- 2
Check the sootblowing log. Count the number of sootblowing cycles per day and compare to the baseline frequency for this load level.[1]
- 3
Inspect the sootblower steam supply pressure at the header. Low supply pressure reduces cleaning reach.
- 4
Run a full sootblowing sequence and log the change in exit temperature before and after. A drop of less than 3 deg C suggests heavy fouling beyond sootblowing capacity.
- 5
If sootblowing is ineffective, schedule an offline water-wash cleaning at the next planned outage.
- 6
During the outage, open the superheater access ports and inspect tube surfaces for hard deposits or tube distortion.[1]
- 7
Document deposit thickness and appearance for the root-cause record before washing.
Sources
ANDRITZ ANDRITZ HERB Recovery Boiler general technical documentation, ANDRITZ
Recovery boiler superheater fouling and sootblowing guidelines, general industry practice (general)
More guides for ANDRITZ ANDRITZ HERB
How to inspect for lower furnace corrosion on an ANDRITZ HERB Recovery Boiler
Lower furnace corrosion typically appears as thinning or pitting on waterwall tubes. Inspect with UT thickness gauging during planned outages and trend wall thickness over time.
How to clear a smelt spout blockage on an ANDRITZ HERB Recovery Boiler
Smelt spout blockage stops flow and risks a dangerous water contact. Shut off wash water, clear the blockage mechanically, then restore wash water before resuming operation.
Related learning guides
Shaft Alignment Fundamentals
Precision alignment that prevents bearing, seal, and coupling failures.
Read guideWhat is Root Cause Analysis (RCA)?
Find the real failure point so the same fault stops showing up every month.
Read guideEquipment Breakdown Response
The step-by-step playbook for the first 15 minutes after a critical machine goes down.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.