TL;DR
A slow rise in differential pressure over months indicates packing fouling. Track the trend, plan an inspection at the next turnaround, and consider a column wash before opening.
What you might see
- differential pressure trend increasing over months
- separation efficiency declining
- solids observed in bottoms product
- increased reboiler duty needed to hold product spec
Likely causes
Solid precipitation from process chemistry depositing on packing surface
Polymerization of reactive feed components coating the packing
Corrosion products from column internals or overhead system washing down
Operator error allowing non-volatile feed component above design rate
Required tools
- Process trend historian access
- Lab solids analysis capability
- Differential pressure transmitter calibration kit
Safety first
- Column internals in pharma service contain hazardous process materials. Any column entry requires a confined space permit, atmospheric testing, and supplied air or SCBA.
- Hot wash or solvent flush procedures must be reviewed against the column pressure rating and relief valve setting before starting.
- Disposed packing material from a fouled column may be classified as hazardous waste. Segregate and label per site procedures.
Procedure
- 1
Pull the differential pressure trend for the last 3 to 6 months. A steady upward trend confirms fouling rather than a transient event.[1]
- 2
Review feed analysis records for periods of elevated solids or reactive components.
- 3
Check overhead condenser and reboiler heat transfer efficiency trends. Fouling in the column often correlates with exchanger fouling.[1]
- 4
Assess whether a hot wash or solvent flush can be performed in-line to reduce fouling before a full turnaround.
- 5
If in-line wash is appropriate, circulate an approved solvent through the column while monitoring differential pressure.
- 6
Add the column to the next turnaround scope for internal inspection, packing removal, and cleaning or replacement.
- 7
Document the fouling history and the suspected chemical cause for the turnaround team.
Sources
Koch-Glitsch (internals) Koch-Glitsch FLEXIPAC / IMTP / Provalve Distillation Column general technical documentation, Koch-Glitsch (internals)
Koch-Glitsch FLEXIPAC / IMTP / Provalve distillation column general packing fouling and inspection procedures (general)
More guides for Koch-Glitsch (internals) Koch-Glitsch FLEXIPAC / IMTP / Provalve
How to diagnose column flooding on a Koch-Glitsch FLEXIPAC / IMTP distillation column
Column flooding causes purity loss and pressure drop spike. Reduce vapor or liquid rate to below the flood point, then diagnose the root cause.
How to diagnose valve tray weeping on a Koch-Glitsch Provalve distillation column
Tray weeping happens when vapor flow is too low to prevent liquid from draining through the tray. Increase vapor load or inspect for damaged valve caps at the next shutdown.
Stop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.