TL;DR
A knock at the crankshaft is almost always bearing wear or inadequate lubrication. Check oil pressure and oil condition before the next production run.
What you might see
- knock or rumble at top of stroke
- vibration at crankshaft housing
- oil pressure warning on crankshaft circuit
- elevated temperature at main crankshaft bearing
Likely causes
Main crankshaft bearing wear from extended service or lubrication starvation
Low lube oil pressure from a worn oil pump or blocked pickup screen
Degraded or contaminated crankshaft lubricant
Loose crankshaft eccentric or connecting rod assembly
Required tools
- Lube oil pressure gauge
- Oil sample collection kit
- LOTO kit
- Replacement oil filter element
- Aida-specified crankshaft lubricant
- Torque wrench (for eccentric bolts)
Safety first
- Stop the press immediately if you hear a new or worsening knock. Running with a failing crankshaft bearing can cause catastrophic mechanical failure.
- Lock out and tag out the main disconnect before opening any crankshaft access panel. The flywheel stores significant rotational energy.
- Insert the die block before entering the press work zone for any internal inspection.
Procedure
- 1
Stop the press immediately if the knock is new or worsening. Continued operation with a bearing knock risks catastrophic crankshaft failure.
- 2
Press the Emergency Stop and lock out the main disconnect.
- 3
Check the crankshaft lube oil level in the reservoir. Add Aida-specified oil if low.
- 4
Check the lube oil pressure gauge reading against the Aida specification. Low oil pressure confirms a lubrication circuit fault.[1]
- 5
Inspect the oil filter and pickup screen for blockage. Replace the filter if the differential pressure indicator shows restriction.[1]
- 6
Take an oil sample from the crankshaft lubrication circuit and send it for spectrographic analysis to check for bearing metal (copper, lead, tin).
- 7
If oil pressure is normal and the oil sample is clean, inspect the crankshaft eccentric bolts for looseness while the main disconnect is locked out.
- 8
If oil analysis shows bearing metal above acceptable limits, stop the press from production use and schedule a crankshaft bearing inspection with an Aida-qualified technician.
Sources
Aida NC1 Mechanical Servo Press Operation Manual, Aida Engineering
Aida NC1 Mechanical Press Operation Manual, crankshaft lubrication and bearing maintenance procedures (general)
View source
More guides for Aida NC1
How to diagnose clutch and brake slipping on an Aida NC1 mechanical press
Clutch or brake slip on the Aida NC1 is a safety-critical condition. Stop production immediately and check air pressure and friction disc thickness before restarting.
How to fix die misalignment on an Aida NC1 mechanical press
Die misalignment on the Aida NC1 is usually worn guide pins or an uneven bolster surface. Measure punch-to-die clearance on all four sides before adjusting anything.
How to stop ram drift on an Aida NC1 mechanical press
Ram drift at rest means hydraulic fluid is bypassing a valve spool or piston seal. Isolate the counterbalance circuit first, then test each valve for internal leakage.
How to fix slow ram speed on an Aida NC1 mechanical press
Slow ram speed on the Aida NC1 usually means worn hydraulic pump output or a pressure relief set too low. Measure pump flow and compare to spec before assuming any single cause.
Related learning guides
Shaft Alignment Fundamentals
Precision alignment that prevents bearing, seal, and coupling failures.
Read guideWhat is Root Cause Analysis (RCA)?
Find the real failure point so the same fault stops showing up every month.
Read guideEquipment Breakdown Response
The step-by-step playbook for the first 15 minutes after a critical machine goes down.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.