Step-by-Step Playbook

The Complete PM
Program Builder

Equipment criticality rankings, a ready-to-use PM task library for 6 equipment types, scheduling templates, and a 12-week implementation timeline.

By Dovient | 20+ pages | Ready to implement

How to Use This Guide

Start by scoring your current PM maturity with the 8 questions below. Then use the criticality matrix to rank your equipment. The PM task library gives you ready-to-use tasks: check the ones you need and copy them to your planning tool.

PM Program Maturity Assessment

Before building anything, you need to know where you stand. Answer these 8 questions honestly to determine your current maturity level and where to focus your energy.

1

What percentage of your maintenance work is reactive (unplanned)?

1
2
3
4
5
2

Do you have written PM procedures for your critical equipment?

1
2
3
4
5
3

Is equipment criticality formally ranked?

1
2
3
4
5
4

Do you have a PM schedule that is followed consistently?

1
2
3
4
5
5

Are PM tasks based on failure mode analysis or just vendor recommendations?

1
2
3
4
5
6

Do you track PM compliance as a KPI?

1
2
3
4
5
7

Are spare parts pre-staged (kitted) for recurring PM tasks?

1
2
3
4
5
8

Do you have a formal process to review and optimize PM frequencies?

1
2
3
4
5
Reactive (8-15)

Start at Section 2. Build criticality ranking first.

Emerging (16-23)

You have basics. Move to Section 3 for the PM task library.

Proactive (24-31)

Solid foundation. Focus on Sections 5-6 for optimization.

Optimized (32-40)

Strong program. Use Section 7 for KPI refinement.

Equipment Criticality Ranking System

Not all equipment deserves the same level of PM attention. This scoring system helps you allocate your limited maintenance resources where they matter most.

EQUIPMENT CRITICALITY RANKING (Example)EquipmentProduction ImpactFailure FreqDetectionScorePriorityAir Compressor #15/53/54/560CRITICALMain Feed Pump5/52/53/530CRITICALCooling Tower Fan4/52/52/516IMPORTANTConveyor Line A3/53/53/527IMPORTANTHVAC Unit 22/52/52/58STANDARDOverhead Crane3/51/53/59STANDARD

Scoring Formula

Criticality Score = Production Impact (1-5) x Failure Frequency (1-5) x Detection Difficulty (1-5)

Critical (40+): Weekly/bi-weekly PM. Predictive monitoring. Insurance spares on-site.
Important (15-39): Monthly PM. Standard spare parts. Documented procedures.
Standard (<15): Quarterly PM or run-to-fail with backup plan.

PM Task Library

This is the most hands-on section: ready-to-use PM tasks for 6 common equipment types. Each task includes what to do, how often, estimated time, skill level required, and parts needed. Use these as your starting point and adjust based on your specific equipment and operating conditions.

Motors: 15 PM Tasks

TaskFrequencyTimeSkillParts/Tools
Visual inspection (leaks, damage, loose connections)Daily5 minBasicFlashlight
Check bearing temperature (IR gun)Weekly10 minBasicIR thermometer
Listen for unusual noise/vibrationWeekly5 minIntermediateStethoscope (optional)
Check terminal connections torqueMonthly15 minIntermediateTorque wrench, insulated tools
Measure insulation resistance (megger test)Quarterly20 minAdvancedMegger tester

10 more motor tasks + 5 other equipment types in the full guide...

Interactive Criticality Scorer

Rate your equipment to calculate its criticality score and get a recommended PM strategy.

Significant slowdown

Occasional (3-5/yr)

Requires trained inspection

27/125
IMPORTANT

Score: 3 x 3 x 3 = 27

Monthly PM. Standard spare parts stocked. Written SOPs available. Include in quarterly vibration route. Review PM findings to optimize frequency.

Interactive PM Task Selector

Select equipment type, check the tasks you want, and copy your customized PM plan.

Daily
Visual inspection (leaks, damage, connections)
5 minBasic
Weekly
Check bearing temperature (IR gun)
10 minBasic
Listen for unusual noise/vibration
5 minIntermediate
Monthly
Check terminal connection torque
15 minIntermediate
Clean exterior, check cooling fins/fan
20 minBasic
Check belt tension and alignment
15 minIntermediate
Grease bearings (per manufacturer)
15 minBasic
Check vibration levels (overall)
20 minIntermediate
Quarterly
Measure insulation resistance (megger)
20 minAdvanced
Check alignment (coupling)
30 minAdvanced
Full vibration spectrum analysis
45 minAdvanced
Semi-annual
Motor current signature analysis
30 minAdvanced
Annual
Full electrical testing
60 minAdvanced
Complete overhaul assessment
90 minAdvanced
0
tasks selected
0.0
est. hours/month
20+ pages